Cut to length line supplier factory today: Poor power quality can severely impact the performance of transformer equipment, leading to a variety of negative outcomes. These consequences not only affect the operational efficiency of the equipment but also pose significant economic concerns. One of the primary damages caused by poor PQ is the deterioration of the transformer’s health. Poor PQ, characterized by factors like voltage sags, swells, harmonics, and transients, can cause excessive heating in transformers. This undue heat can degrade the insulation material used in transformers, subsequently reducing their lifespan and potentially leading to catastrophic failures. Therefore, poor power quality can lead to considerable damage to transformer equipment, resulting in economic losses, reduced energy efficiency, and decreased productivity. Therefore, maintaining high power quality is crucial for the optimal performance of transformer equipment and overall operational efficiency. Find extra info at slitting line machine.

What does the rated value on the nameplate of the transformer mean? The rated value on the transformer nameplate refers to some important electrical parameters and performance indicators of the transformer. Usually includes the following aspects: Rated capacity: The rated capacity of a transformer refers to the maximum load electric power that the transformer can continuously supply. For example, a 10MVA transformer means that the transformer’s maximum load can reach 10 megawatts. Rated voltage: The rated voltage of the transformer refers to the design voltage of the transformer. For example, a 220kV/110kV transformer means that the input voltage of the transformer is 220 kV and the output voltage is 110 kV. Rated frequency: The rated frequency of a transformer refers to the power frequency for which the transformer is designed. In China, the power frequency is usually 50Hz. Short-time withstand current: The short-time withstand current of a transformer refers to the maximum current value that the transformer can withstand in a short period of time. For example, the short-term withstand current of a transformer is 50kA, which means that the transformer can withstand an instantaneous current of up to 50 kA.

What is eddy current? What are the disadvantages of eddy current generation? Eddy current refers to a kind of current generated in the conductor, which is the induced current caused by the change of the magnetic field. The eddy current forms a circular current flow path in the conductor, and this current forms a motion state similar to an eddy current inside the conductor, so it is called an eddy current. The generation of eddy currents has the following disadvantages: Energy loss: Eddy currents create circular currents in conductors, which generate heat as they flow continuously in conductors. Since the generation of eddy currents is caused by changes in the magnetic field, in equipment such as transformers and motors.

The company mainly produces 150 model oil-type transformercore shearing equipment below 1 600KVA, 300 model dry type transformer core shearing equipment below 6300KVA, 400 model special transformer core shearing equipment below 12500KVA and 600 model special transformer core shearing equipment below 63000KVA. 800 model extra transformer core shearing equipment, 1000 model extra transformer core shearing equipment, the type 1250 model CRGsilicon steel CNC slitting machine, and the dry type transformer core under 110KV automatic cutting and laminated processing center, oil transformer core automatic cutting robot automatic lamination processing center, reactor cutting center below 35Kv, 220KV high voltage transformer tc. CANWIN hire famous designer in Europe as our senior consultant, and germany Siemens as our strategic partner. The products have formed 5 series and more than 50 specifications.

Canwin is a professional ctl line manufacturers & suppliers china, we have been specialized in ctl machines for over 20 years.This cut to length production line adopts advanced control system to ensure the accurate and stable operation of the cut to length production line. Embedded operating terminal can complete parameter setting quickly and conveniently. After the coil material of silicon steel sheet is punched and cut into certain shape and size by this cut to length production line, the classification and finishing work is completed at the end of the production line, and it is automatically stacked into 20 columns and used for the core assembly.

Three-dimensional wound core transformer breaks through the traditional triangle plane structure, adopts three-phase symmetric vertical structure, magnetic circuit completely symmetrical three-phase core products, magnetic resistance is greatly reduced, excitation current, no-load loss, is a kind of using traditional materials, but lower operating noise, structure is more compact and efficient energy-saving oil type transformer. Its excellent performance in energy saving and energy saving and environmental protection is in line with China’s energy conservation policy.

A transformer core is a static device that provides a channel for magnetic flux to flow in a transformer. The core is constructed using thin strips of silicone steel. The silicon steel sheets are electrically isolated and coupled to reduce no-load losses in the transformer.The core of a transformer is made of soft iron. Transformers are used in various fields like power generation grid, distribution sector, transmission, and electric energy consumption.

The transformer core provides a magnetic path to channel flux. The use of highly permeable material (which describes the material’s ability to carry flux), as well as better core construction techniques, helps provide a desirable, low reluctance flux path and confine lines of flux to the core. An electrical distribution cabinet is a part of an electrical system whose task is to distribute electrical energy. It includes distribution, protection, measurement, control and signaling instruments. The electrical distribution box also contains wires, various types of insulation, and support components. Read additional information on https://www.canwindg.com/

Laser welding machine is an efficient and precise welding method using high energy density laser beam as a heat source. Laser welding is one of the important applications of laser material processing technology. It mainly used for welding thin wall material and low speed in the 1970 s. The welding process is thermal conduction, i.e. the laser radiation heating surface, the surface heat to the internal diffusion through heat conduction, by controlling the width of laser pulse, energy, peak power and repeating frequency, parameters such as melting of components, to form specific molten pool. Because of its unique advantages, it has been successfully used in precision welding of micro and small parts.As one of the best laser welding machine manufacturers in China, Canwin specialized in handheld laser welding machine and wholesale fiber laser welding machine making for over 20 years.

The main pillar of the smart grid is the smart substation, which is not only an important hub for power transmission and distribution, but also directly affects the operational and monitoring capabilities of the smart grid through its operational safety and stability. Through the network, information can be exchanged, and the transformer can share information with the process layer and the station control layer. On the premise of ensuring product performance, the integration of monitoring, control, measurement, protection, and metering is designed to achieve the integration of transformer components with actuators, sensors, and transformers.

Connection group label: According to the phase relationship between the primary and secondary windings of the transformer, the transformer windings are connected into various combinations, which are called the connection group of the windings. In order to distinguish different connection groups, the clock notation is often used, that is, the phasor of the line voltage on the high-voltage side is used as the long hand of the clock, fixed at 12, and the phasor of the line voltage on the low-voltage side is used as the short hand of the clock. The number of the short hand indicates the connection group label. For example, Dyn11 indicates that the primary winding is (triangle) connected, and the secondary winding is (star) connected with a center point, and the group number is (11) points.